Threads
A thread is the feature most likely to fail at assembly and the one most often specified with a single note: “M6”. The class, the hole size, the material and the assembly frequency decide whether it starts cleanly or galls on the third disassembly.
Quick answer
Specify the thread class (6H for a nut, 6g for a bolt), the minimum engagement and the material. In stainless and titanium, plan for galling: use the right class, a thread insert for repeated assembly, and a test piece. For large or awkward threads, thread milling is often more reliable than tapping. Check the thread with a go/no-go gauge, not a bolt from the bin.

Thread classes in one table
| Class | Where it is used | What it means |
|---|---|---|
| 6H | Internal thread (nut) | Standard tolerance for a mating 6g bolt; the common default for machined parts |
| 6g | External thread (bolt) | Standard tolerance with a small allowance; the common default for a plated or coated bolt |
| 5H / 4H | Internal, tighter | Less clearance; used for precision or preload-critical joints |
| 6H mod | Internal, with allowance | Used when the thread will be coated or anodised; the allowance protects the fit |
| 8G | Internal, loose | More clearance for difficult materials or quick assembly |
A thread class is a tolerance, not a quality grade. A 6H thread is not “better” than a 6H mod; it is a different fit. If the part is anodised or plated, the coating builds on the flanks; a standard 6H may become too tight. Mask the thread or use a class with an allowance.
Hole size and engagement
The tap drill size decides the thread’s minor diameter and the percentage of thread engagement. A hole that is too small overloads the tap and can break it; a hole that is too large gives a weak thread. The standard tap drill chart is a starting point, but the material and the class matter.
Engagement matters more than depth. A thread that is 1.5× diameter deep in aluminium may strip before a 1× diameter thread in steel. For soft materials, use a thread insert or increase the engagement. For repeated assembly, a thread insert is often the right answer, not a deeper thread.
Tapping vs thread milling
Tapping is fast and common for small threads in a drilled hole. It needs the right tap, the right lubricant and a hole that is straight. In stainless and titanium, a worn tap galls and tears the thread; a new, coated tap and a test piece are cheaper than a rework.
Thread milling uses a rotating cutter on a helical path. It is slower per hole but more forgiving: one tool can cut several thread sizes, the thread is clean, and the risk of a broken tap in a large part is lower. It is the better choice for large threads, hard materials, awkward locations and parts where a broken tap would be expensive.
At GY we tap and thread-mill depending on the size, material and location. The quote should say which route is used if the thread is critical.

Galling in stainless and titanium
Galling is cold welding: the bolt and the thread seize and tear the surface. Stainless and titanium are both prone to it, especially with stainless-on-stainless or titanium-on-titanium joints. The thread class alone does not prevent it.
The practical controls are: a slightly looser class, a lubricant, a thread insert, a different material for the fastener, and a limit on the assembly torque. For a joint that will be disassembled repeatedly, a thread insert (helical or solid) is often the most reliable answer. It also lets you replace the wear surface without remaking the part.
Threads in soft plastics
PTFE, POM and PEEK behave differently from metal. PTFE cold-flows; a thread can creep under load. POM cuts cleanly but strips if the engagement is short. PEEK is stronger but galls and is expensive. For soft plastics, a thread insert or a metal nut is often better than a tapped plastic thread, especially if the joint is opened more than once.
If the design uses a self-tapping screw in plastic, specify the boss diameter and the screw type. A thread designed for metal may split the boss or strip on the first assembly.
How to inspect a thread
A go/no-go gauge is the standard check. The go gauge must enter the full thread; the no-go gauge must not. A bolt from the bin is not a gauge: it may be undersized, worn or plated, and it does not prove the class.
For critical threads, check the minor diameter, the pitch diameter and the thread depth. On the first article, record the gauge result and the thread depth. If the part is coated, check the thread after coating or confirm that it was masked.

Thread milling vs tapping: a cost comparison
Tapping is usually faster per hole, but it is not always cheaper. A broken tap in a large part can cost more than the entire milling operation, and a tap that is slightly worn can tear a thread in stainless or titanium.
| Factor | Tapping | Thread milling |
|---|---|---|
| Cycle time per hole | Short | Longer (helical path) |
| Tool cost | Low per tap, but taps wear and break | Higher per cutter; one cutter covers several sizes |
| Thread quality | Good if the tap is sharp and the hole is straight | Clean, controllable, good in hard materials |
| Broken tool risk | High in small/deep holes and hard materials | Low; a broken cutter is rare |
| Best batch | High volume, small threads, soft materials | Large threads, hard materials, awkward locations, low volume |
For 1,000 M3 holes in aluminium, tapping is usually the right route. For 20 M20 holes in 316 stainless, thread milling is often cheaper once the broken-tap risk is included. The quote should say which route is used if the thread is critical.
Thread classes and coating allowance
A standard 6H internal thread is designed for a 6g bolt with no coating. If the part is anodised, plated or powder-coated, the coating builds on the flanks and the thread becomes tight. The usual solutions are to mask the thread or to specify a class with an allowance, such as 6H mod.
The allowance depends on the coating thickness. Type II anodising is 5–20 µm; Type III is 25–50 µm; plating can be 5–25 µm. A 20 µm coating on each flank can reduce the pitch diameter enough to make a standard bolt bind. Masking is more reliable than guessing an allowance, especially on small threads.
If the thread must be coated, put the allowance on the drawing and prove it with a go/no-go gauge after coating. Do not assume the coater will “keep it loose”.
Galling: a materials table
| Pair | Galling risk | What to do |
|---|---|---|
| Stainless bolt / stainless thread | High | Anti-seize, a different alloy, or a thread insert |
| Titanium bolt / titanium thread | Very high | Dry-film lubricant, insert, or a different pairing |
| Steel bolt / aluminium thread | Medium | Insert or increased engagement; aluminium threads wear |
| Steel bolt / brass thread | Low–medium | Lubricant; avoid over-torque |
| Plastic thread / metal bolt | Low, but strips | Insert or a coarser thread with more engagement |
Galling is not a lubrication-only problem. It is pressure, material pair, surface finish and assembly speed. A thread insert removes the stainless-on-stainless or titanium-on-titanium couple and gives you a replaceable wear surface.
Design rules for blind, deep and cross threads
- Blind holes need a tap drill depth and a thread depth. A thread that runs to the bottom of a blind hole packs chips and breaks taps. Leave 2–3 pitches of clearance below the thread.
- Deep small threads are a trap. A long, small tap is fragile; the deeper the hole, the higher the break risk. If the thread must be deep, consider thread milling.
- Cross-holes need a deburr plan. A cross-hole intersects the thread and leaves a burr inside. Specify the deburr and inspect the thread after it.
- Thread relief helps. A relief groove at the end of a thread gives the tool room to stop and avoids a partial thread.
- Engagement beats depth. In aluminium, 1.5× diameter engagement is often better than a deeper thread with a thin wall.
Thread inspection and sampling
A go/no-go gauge is the first check. The go gauge must enter the full thread; the no-go must not. For a critical thread, check the minor diameter, the pitch diameter and the depth on the first article. For production, sample every 10th or 20th part, and after every tap change.
If the part is coated, inspect after coating or confirm the masking. A thread that passes before anodising and fails after is a masking problem, not a tapping problem.
A worked example
An M6 thread in 6061, 12 mm deep, 100 parts. Tapping is fast: a spot drill, a 5.0 mm tap drill and a forming or cutting tap. The risk is low if the tap is new and the hole is straight. The thread is checked with a 6H go/no-go gauge.
The same thread in 316 stainless, 12 mm deep, 20 parts. Tapping is slower and the galling risk is higher; a sharp, coated tap and a lubricant are essential. If the part is large and a broken tap would be expensive, thread milling is the safer route, even at a higher cycle time. The quote should reflect the risk, not just the hole count.
Thread standards: metric, UNC, UNF, NPT and BSP
Most machined parts use one of five thread families. The choice is usually set by the mating part or the market, not by the machine shop. Mixing families on one drawing is a common source of assembly errors.
| Family | Example | Where it is used | Watch |
|---|---|---|---|
| Metric coarse | M6 × 1 | General machinery, European and Asian parts | Default unless the drawing says otherwise |
| Metric fine | M8 × 1 | Thin walls, adjustment, automotive | Less engagement per turn; check depth |
| UNC / UNF | 1/4-20, 10-32 | US-designed equipment, optics, firearms | Do not substitute metric on a US assembly |
| NPT | 1/8-27 NPT | Pipe threads, pneumatics, hydraulics | Taper thread; sealing depends on engagement |
| BSP / BSPP | G 1/4 | European pipe fittings | Parallel vs tapered; sealing washer |
A drawing that says “M6” means metric coarse unless a pitch is specified. A drawing that says “1/4-20” means UNC. If the mating part is unknown, do not guess; send the mating thread or the assembly drawing.
Thread depth and engagement by material
| Material | Typical engagement | Notes |
|---|---|---|
| Steel | 1.0× diameter | Standard; a longer thread adds little |
| Aluminium | 1.5–2.0× diameter | Threads strip; consider an insert for repeated assembly |
| Brass | 1.5× diameter | Good machinability; avoid over-torque |
| Stainless | 1.0–1.5× diameter | Galling risk; lubricant or insert |
| Titanium | 1.0–1.5× diameter | Galling; use a dry-film lubricant or insert |
| POM / PEEK | 1.5–2.0× diameter | Creep and strip; inserts for repeated use |
Engagement is not the same as thread depth. A blind hole needs a tap drill depth, a thread depth and a clearance below the thread. If the drawing gives only “M6 × 12 deep”, the shop has to decide whether 12 mm is the thread or the drill. Say which.
A supplier checklist for threaded parts
- Thread standard, size and pitch.
- Class (6H, 6H mod) and coating/masking plan.
- Thread depth and drill depth, especially for blind holes.
- Engagement required for the material.
- Whether an insert is allowed or required.
- Inspection: go/no-go gauge, first article, sampling.
- Galling risk and lubricant/insert for stainless or titanium.
- Deburr plan for cross-holes and blind holes.
Common mistakes
- “M6” with no class. The shop will choose; the assembly may not agree.
- Anodising an unmasked thread. The coating builds on the flanks and the bolt will not start.
- Too short an engagement in aluminium. The thread strips before the bolt breaks.
- A worn tap in stainless. The thread tears or galls; a new tap and a test piece are cheaper.
- No lubricant on a stainless joint. Galling is a function of pressure and material, not just torque.
- Checking with a bolt instead of a gauge. A bolt proves that one bolt fits, not that the thread is in tolerance.
FAQ
What does 6H mean on a thread?
6H is the standard internal thread tolerance for a mating 6g bolt. It is the common default for a machined nut or tapped hole.
Should I use a thread insert?
For repeated assembly, soft materials or a joint that must not gall, a thread insert is often the most reliable choice.
Can you tap titanium?
Yes, with a sharp, coated tap, the right lubricant and a test piece. Titanium galls; a worn tap will tear the thread.
Can a thread be anodised?
It can, but the coating builds on the flanks and changes the fit. Most production parts mask threads or use an allowance.
What is the best way to check a thread?
A go/no-go gauge. A bolt from the bin is not a gauge and does not prove the thread class.
Do you thread mill?
Yes, for large threads, hard materials and locations where a broken tap would be expensive. We also tap small threads where it is the efficient route.
What we see at GY on threaded parts
“M6” with no class or depth. The shop chooses; the assembly may not agree. A thread callout should include the standard, the size, the pitch if it is fine, the class and the depth.
Anodising without masking. The coating builds on the flanks and the bolt will not start. Masking the thread is cheaper than re-tapping a coated part.
A worn tap in stainless. The thread tears or galls. A new, coated tap and a test piece are cheaper than a rework.
A blind hole with no clearance. The thread runs to the bottom, the tap packs chips and breaks. Leave 2–3 pitches below the thread.
No insert on a repeated joint. Aluminium or plastic threads wear out. A thread insert is a replaceable wear surface and often the right answer.
A bolt used as a gauge. A bolt proves that one bolt fits, not that the thread is in tolerance. Use a go/no-go gauge.
A 10-point checklist for threaded parts
- Thread standard (metric, UNC, UNF, NPT, BSP).
- Size, pitch and class.
- Thread depth and drill depth.
- Engagement for the material.
- Coating and masking plan.
- Insert allowed or required.
- Galling risk and lubricant.
- Deburr plan for cross-holes.
- Inspection: go/no-go, first article, sampling.
- Assembly torque and repeated-use requirement.