Medical machining
Medical device work is not one market. Instrument housings, lab equipment, fixtures and development parts are a different problem from implants and sterile disposables. The first group can be machined by a precision shop with a measuring room; the second needs a quality system and a cleanroom that most machine shops do not have.
Quick answer
We are not ISO 13485 certified and we do not have a cleanroom. We machine instrument hardware, manifold blocks, fixtures and PEEK/POM components, inspect them on a CMM and provide a dimensional report with every batch. If your process requires ISO 13485 or sterile packaging, we will say so in the first reply — not at audit.

What medical buyers actually need
Most of the medical RFQs we see are not implants. They are instrument housings, manifold blocks, brackets, test fixtures, lab equipment parts and prototypes. The materials are usually 6061 or 7075 aluminium, 316L stainless, titanium Grade 5, PEEK, POM or PAI.
The requirements that matter are dimensional: a bore that aligns, a flat face that seals, a burr-free edge that will be handled, a thread that will not gall. The quality system matters too, but it is a gate, not a substitute for the measurement. A supplier can have a certificate and still ship a bore that is 0.03 mm out.
Materials we machine
| Material | Typical medical use | Watch |
|---|---|---|
| Ti-6Al-4V (Grade 5) | Instrument bodies, frames, wear parts | Galling in threads; heat at the cut; cost |
| 316L stainless | Housings, fittings, manifolds | Work-hardening; passivation after machining |
| 6061-T6 aluminium | Instrument housings, fixtures, base plates | Anodising and fits; thin-wall distortion |
| PEEK | Insulators, manifolds, low-outgassing parts | Annealing; cost; dimensional movement |
| POM / PAI | Bushings, covers, wear parts | Creep; cleaning agents; clamping marks |
We can supply EN 10204 3.1 mill certificates for metal, and material lot traceability through the job. If your procedure needs a specific certificate or a declared sub-supplier, tell us at the quote stage; it changes the material sourcing and the price.
Tolerances and features
Medical instrument parts often combine a tight bore, a flat sealing face and a burr-free edge. The bore may be ±0.005 mm; the flatness 0.02 mm; the edge a 0.2 mm radius with no burr. Each of those is a different process and a different inspection.
We hold ±0.002 mm on critical milled features and IT6–IT8 fits on turned parts, but we do not apply those numbers to every dimension. The drawing should mark the critical few and use ISO 2768-mK for the rest. A global ±0.01 on an instrument housing adds inspection and slower cuts without improving the function.
Burrs deserve their own note. A burr on an internal bore can trap contamination or damage a seal. Specify the edge break and the inspection method; “deburr” alone is not a specification.

Cleanliness and passivation
Machining leaves coolant, chips and handling marks. For a medical instrument part, the cleaning step is part of the process, not a final wipe. We clean parts in an ultrasonic bath, dry them, and pack them in clean bags. For stainless, passivation is handled by a finishing partner and checked before packing.
We do not have a cleanroom. If the part must be packed in a cleanroom, sterilised or supplied sterile, we are not the right supplier for that step. We can machine and clean the component and hand it to a qualified partner, but we will not pretend the bag on our bench is a cleanroom pack.
Traceability and documentation
Every batch can carry a first-article dimensional report, material certificates, a material lot number and a packing list. The report shows the nominal, the tolerance, the actual value and the instrument. If a characteristic is out, the report shows the correction and the re-check, not a cleaned-up number.
What we do not have is ISO 13485. If your supplier approval requires it, we are not a candidate, and we will tell you in the first email. For instrument hardware and development parts, many buyers approve a supplier on measured results and a sample order; if your process cannot, we would rather you know now.
DFM for medical parts
- Thin walls and deep pockets. A 1 mm wall in aluminium deflects; a deep pocket with a small corner radius needs a long tool. Both add cost and risk.
- Sharp internal corners. They cannot be milled; they need EDM or a relief. A small radius is usually cheaper.
- Blind holes and cross-holes. They trap chips and cleaning fluid. Say whether the hole must be through or blind, and how it will be cleaned.
- Threads in titanium and stainless. Galling is a real risk. Specify the thread class and use a thread insert if the joint is assembled repeatedly.
- Surface finish by function. A seal face and a cosmetic cover do not need the same Ra. Mark the area that matters.
- Sterilisation compatibility. If the part will be autoclaved or chemically sterilised, say so; the material and the finish may need to change.
What we say no to
We do not claim ISO 13485, a cleanroom, sterile packaging or implant experience. If the part is an implant, a sterile disposable or a regulated assembly that requires a certified quality system, we are not the right supplier. Saying that early is cheaper for both sides than discovering it at audit.
What we can do is machine the component, inspect it, document it and manage the finishing. For instrument hardware, lab equipment, fixtures and development parts, that is often enough.
A real example
A laboratory instrument housing in 6061-T6, anodised black, with a Ø12 H7 bore, a flat sealing face and a 0.5 mm wall around a display window. The first design had a square internal corner in a 15 mm deep pocket and a global ±0.01 tolerance. The corner forced EDM; the tolerance added inspection on every face.
We changed the corner to a 3 mm radius, kept ±0.01 on the bore and the sealing face, and used ISO 2768-mK elsewhere. The part was machined in two setups, anodised with the bore masked, and checked on the CMM. The first article passed, and the batch shipped with a dimensional report and material certificate.
The customer did not need ISO 13485 for that instrument; they needed a supplier who could read the drawing and prove the bore. That is a different qualification, and it is the one we can meet.
What medical parts can you machine?
The parts that fit our shop are instrument housings, manifold blocks, brackets, fixtures, lab-equipment components and PEEK or POM parts. They are handled, assembled and cleaned, but they are not implanted and they are not sterile disposables.
Typical parts include a 6061 instrument housing with an anodised finish, a 316L manifold with a sealing face, a PEEK insulator and a POM cover. The acceptance criteria are dimensional and cleanliness-related; the quality system is a separate gate.
Which material should I specify?
| Material | Typical use | What to watch |
|---|---|---|
| Ti-6Al-4V | Instrument bodies, frames, wear parts | Galling; heat; cost |
| 316L stainless | Housings, fittings, manifolds | Passivation; work-hardening |
| 6061-T6 aluminium | Instrument housings, fixtures, base plates | Anodising; thin-wall distortion |
| PEEK | Insulators, manifolds, low-outgassing parts | Annealing; cost; movement |
| POM / PAI | Bushings, covers, wear parts | Creep; cleaning agents; clamping marks |
If the part will be autoclaved or chemically sterilised, say so. The material and the finish may need to change; a coating that survives one cleaning agent may fail another. A material certificate and lot traceability are available on request.
What tolerances and finishes matter?
A medical instrument part often combines a tight bore, a flat sealing face and a burr-free edge. The bore may be ±0.005 mm, the flatness 0.02 mm, and the edge a 0.2 mm radius with no burr. Each is a different process and a different inspection.
We hold ±0.002 mm on critical milled features and IT6–IT8 fits on turned parts, but we do not apply those numbers to every dimension. Mark the critical few and use ISO 2768-mK for the rest. Burrs deserve their own note: a burr in a bore can trap contamination or damage a seal.
Anodising and passivation change the surface and sometimes the fit. Mask bores and threads, or specify the fit after finishing. For stainless, passivation is handled by a finishing partner and checked before packing.
What documentation can you provide?
A first-article dimensional report, material certificates, lot number and packing list. The report shows the nominal, the tolerance, the actual value and the instrument. If a characteristic is out, it shows the correction and the re-check.
We are not ISO 13485 certified and we do not have a cleanroom. If your process requires those, we are not the right supplier, and we will say so in the first reply. For instrument hardware and development parts, the measured report is often the evidence the buyer needs.
Before you send a medical part
- Material, certificate and lot traceability.
- Critical dimensions and inspection method.
- Burr and edge requirements.
- Cleaning, passivation and packaging.
- Sterilisation or cleaning-agent exposure.
- Whether ISO 13485/cleanroom is a hard requirement.
What does a medical part cost?
Take a 6061 instrument housing, 120 × 80 × 30 mm, anodised black, with a Ø12 H7 bore, a flat sealing face and a burr-free edge. At 50 pieces, the setup, first article and finishing minimum are a large share of the price; at 500, the machining cycle and inspection dominate.
| Cost line | What drives it | How to reduce it |
|---|---|---|
| Material | Grade, size, certificate | Use a standard plate close to finished size |
| Machining | Bore, pocket, edge breaks | Relax non-critical tolerances |
| Finishing | Anodising, masking, batch minimum | Mask only the features that matter |
| Inspection | FAI, CMM, report | Inspect the critical characteristics |
| Cleaning/packing | Ultrasonic, bagging | Plan drainage and handling |
A real example: an instrument housing
A laboratory instrument housing in 6061-T6, anodised black, with a Ø12 H7 bore, a flat sealing face and a 0.5 mm wall around a display window. The first design had a square internal corner in a 15 mm deep pocket and a global ±0.01 tolerance. The corner forced EDM; the tolerance added inspection on every face.
We changed the corner to a 3 mm radius, kept ±0.01 on the bore and the sealing face, and used ISO 2768-mK elsewhere. The part was machined in two setups, anodised with the bore masked, and checked on the CMM. The first article passed, and the batch shipped with a dimensional report and material certificate.
The customer did not need ISO 13485 for that instrument; they needed a supplier who could read the drawing and prove the bore. That is a different qualification, and it is the one we can meet.
Before you order a medical part
- Material and certificate.
- Critical bore, flatness and edge requirements.
- Finishing and masking.
- Cleaning and packaging.
- FAI and report level.
- ISO 13485/cleanroom requirement.
How do I specify a burr-free edge?
“Deburr” is not a specification. A burr-free edge needs a radius or a chamfer, a maximum edge break, and an inspection method. A 0.2 mm radius with no visible burr is a different requirement from a 0.05 mm edge break on a sealing face.
The deburr method matters. A hand tool can round an edge unevenly; a CNC chamfer tool is more consistent; a vibratory or electrochemical process can deburr many parts at once but may change the edge radius. For a medical or vacuum part, the edge and the cleaning are linked: a burr can trap contamination, and a rough deburr can create particles.
Put the edge requirement on the drawing and inspect the first article under the agreed light. If the edge is critical, add a profile or radius callout, not just a note.
Medical part order checklist
- Material, certificate and lot.
- Critical bore, flatness and edge requirements.
- Deburr method and inspection.
- Cleaning, passivation and packaging.
- FAI and report level.
- ISO 13485/cleanroom requirement.
FAQ
Are you ISO 13485 certified?
No. We say so in the first reply. We machine instrument hardware and development parts, inspect them and provide reports, but we are not a certified medical device manufacturer.
Can you machine implantable parts?
No. Implants require a certified quality system, validated processes and cleanroom controls that we do not have.
Do you provide material certificates?
Yes, EN 10204 3.1 mill certificates for metal on request, with lot traceability through the job.
Can you passivate stainless parts?
We manage passivation through a finishing partner and check the parts before packing. We do not run the passivation bath in-house.
Do you have a cleanroom?
No. We can ultrasonically clean and bag parts, but we do not claim cleanroom packaging or sterilisation.
What documentation comes with a batch?
A first-article dimensional report, material certificates, lot number and packing list. The report shows the instrument and the actual values.
Related reading
- Materials guide: aluminium, titanium and plastics
- Medical device CNC machining at GY
- How to read a first article inspection report
- PEEK machining service
- Quality and inspection at GY Machining
- CNC Machining for Semiconductor Equipment: Cleanliness, Flatness and Materials
- GD&T Flatness Explained: How to Specify, Measure and Avoid Paying for It